Sign In

  • Forgot your password?
  • Need a new account?

Register


DA 47MF

MODEL:DA 47MF

4-6 Weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


DT 47L - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
Thread M40 x 1.5 Length 124mm

DA 47G - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
5

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
50 to 1300 | 100 to 1800 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 x 1.5 Length 124mm

DA 47F - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
3.9

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 x 1.5 Length 124mm

DA 47MF - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
3.5 to 4.0

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
50 to 1000

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 x 1.5 Length 124mm

DA 47M - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
20 to 850 | 30 to 1000

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 x 1.5 Length 124mm

DSF 44N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70 (Pyrometer) | 0 to 250 (fibre cable with optical head) | 0 to 150 (fibre cable with 90° curve)

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DT 44L - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
8 to 14

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
–40 to 1000 | 0 to 1000

NETD (k)

Adjustable Response Time

Adjustable Emissivity ε
0.200 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DA 44G - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
5

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
50 to 1300 | 100 to 1800 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 126 mm

DA 44F - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
3.9

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
100 to 1400 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 126 mm

DA 44MF - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
3.5 to 4.0

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
50 to 1000

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 126 mm

DA 44M - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.6% or 1 K

Spectral range (µm)
3 to 5

Distance ratio
50:1

Reproducibility
0.3% or 0.5 K

Temperature Range (°C)
20 to 850 | 30 to 1000

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 126 mm

DGE 44N - Parameter

Weight (g)
455

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 2 K

Spectral range (µm)
2.0 to 2.6

Distance ratio

Reproducibility
0.3% + 1 K

Temperature Range (°C)

NETD (k)
0.5

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DG 44N - Parameter

Weight (g)
455

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DGF 44N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70 (Pyrometer) | 0 to 250 (fibre cable with optical head) | 0 to 150 (fibre cable with 90° curve)

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DS 44N - Parameter

Weight (g)
455

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DSR 44N - Parameter

Weight (g)
455

Operating Temperature (°C)
0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Distance ratio

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.05 - 1.00 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DSRF 44N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70 (pyrometer) | 0 to 250 (fibre cable and optical head)

Housing
stainless steel housing with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.7 to 1.1

Distance ratio

Reproducibility
0.2% + 0.5 K

Temperature Range (°C)

NETD (k)
0.1

Adjustable Response Time
5ms to 100s via RS-485 interface

Adjustable Emissivity ε
0.050 - 1.000 via RS-485 interface

Dimensions
Thread M40 × 1.5 length 125 mm

DG 42N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 × 1,5 length 125 mm

DS 42N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε
0.050 - 1.00

Dimensions
Thread M40 × 1,5 length 125 mm

DT 42G - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)
5

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)
100 to 1300 | 500 to 2500

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
Thread M40 × 1,5 length 125 mm

DT 42L - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
8 to 14

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)
–40 to 1000

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
Thread M40 × 1,5 length 125 mm

DT 40U - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)
300 to 1100

NETD (k)
0.1

Adjustable Response Time
60ms to 100s via USB interface

Adjustable Emissivity ε
0.200 - 1.000 via USB interface

Dimensions

DT 40G - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)
5

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)
100 to 1300 | 200 to 1400 | 500 to 2500

NETD (k)

Adjustable Response Time
60ms to 100s via USB interface

Adjustable Emissivity ε
0.200 - 1.000 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DT 40F - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)
3.9

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)
300 to 1300 | 400 to 1400 500 to 2500

NETD (k)
0.1

Adjustable Response Time
60ms to 100s via USB interface

Adjustable Emissivity ε
0.200 - 1.000 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DGF 40N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70 (pyrometer) | 0 to 250 (fibre cable and optical head) | 0 to 150 (fibre cable with 90° curve)

Housing
stainless steel with plug connector and protection window

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)
0.1

Adjustable Response Time
10ms to 100s via USB interface

Adjustable Emissivity ε
0.05 - 1.00 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DS 40N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector and protection window

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
200:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)
0.1

Adjustable Response Time
10ms to 100s via USB interface

Adjustable Emissivity ε
0.05 - 1.00 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DSF 40N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70 (pyrometer) | 0 to 250 (fibre cable and optical head) | 0 to 150 (fibre cable with 90° curve)

Housing
stainless steel with plug connector and protection window

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 250 to 2000 | 350 bis 1800

NETD (k)
0.1

Adjustable Response Time
10ms to 100s via USB interface

Adjustable Emissivity ε
0.05 - 1.00 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DG 40N - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector and protection window

Measurement Uncertainty
0.5% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
200:1

Reproducibility
0.1% + 0.5 K

Temperature Range (°C)
600 to 1800 | 0 to 2500 | 250 to 1300 | 350 to 1800 | 250 to 2000

NETD (k)
0.1

Adjustable Response Time
10ms to 100s via USB interface

Adjustable Emissivity ε
0.05 - 1.00 via USB interface

Dimensions
Thread M40 × 1.5 length 125 mm

DT 40L - Parameter

Weight (g)
450

Operating Temperature (°C)
0 to 70

Housing
stainless steel with plug connector

Measurement Uncertainty

Spectral range (µm)
8 to 14

Distance ratio
50:1

Reproducibility

Temperature Range (°C)
–40 to 1000 | 0 to 1000

NETD (k)
0.1

Adjustable Response Time
60ms to 100s via USB interface

Adjustable Emissivity ε
0.200 - 1.000 via USB interface

Dimensions

DS 4N - Parameter

Weight (g)
500

Operating Temperature (°C)
sensor head: 0 to 125 | electronics box: 0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
1.0% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
110 mm × 80 mm × 40 mm (electronics box)

DG 4N - Parameter

Weight (g)
500

Operating Temperature (°C)
sensor head: 0 to 125 | electronics box: 0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
1.0% + 1 K

Spectral range (µm)
0.8 to 1.1 | 1.5 to 1.8

Distance ratio
50:1

Reproducibility

Temperature Range (°C)
600 to 1800 | 800 to 2500 | 250 to 1300 | 350 to 1800

NETD (k)
0.1

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
110 mm × 80 mm × 40 mm (electronics box)

DT 4G - Parameter

Weight (g)
500

Operating Temperature (°C)
head: 0 to 125 | electronics box: 0 to 70

Housing
stainless steel housing with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)
5

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)

NETD (k)

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
110 mm × 80 mm × 40 mm (electronics box)

DT 4L - Parameter

Weight (g)
500

Operating Temperature (°C)
head: 0 to 125 | electronics box: 0 to 70 | head: 0 to 180

Housing
stainless steel housing with plug connector

Measurement Uncertainty
1.0% or 1 K

Spectral range (µm)
8 to 14

Distance ratio
50:1

Reproducibility
0.5% or 0.5 K

Temperature Range (°C)

NETD (k)

Adjustable Response Time

Adjustable Emissivity ε

Dimensions
110 mm × 80 mm × 40 mm (electronics box)

DT 47L - Download

DA 47G - Download

DA 47F - Download

DA 47MF - Download

DA 47M - Download

DSF 44N - Download

DT 44L - Download

DA 44G - Download

DA 44F - Download

DA 44MF - Download

DA 44M - Download

DGE 44N - Download

DG 44N - Download

DGF 44N - Download

DS 44N - Download

DSR 44N - Download

DSRF 44N - Download

DG 42N - Download

DS 42N - Download

DT 42G - Download

DT 42L - Download

DT 40U - Download

DT 40G - Download

DT 40F - Download

DGF 40N - Download

DS 40N - Download

DSF 40N - Download

DG 40N - Download

DT 40L - Download

DS 4N - Download

DG 4N - Download

DT 4G - Download

DT 4L - Download