Sign In

  • Forgot your password?
  • Need a new account?

Register


Near Infrared Spectrometer 900-2500nm | SIMTRUM Photonics Store

Near Infrared Spectrometer 900-2500nm

The N Series Cooled NIR Fiber Spectrometer is the core component that adopts an InGaAs linear image sensor, which has high sensitivity and stability in the near-infrared region. It is professional spectroscopy equipment for scientific research-grade near-infrared applications. It has the characteristics of small size, easy operation, and excellent performance.


Features

•  Support GPIO 

•  Cooled InGaAs Detectors 

•  Batch Consistency Control 

•  High signal-to-noise ratio, low stray light 

•  Transmitted Light Paths

Technical Advantages

1. High sensitivity, high dynamic range

The N series spectrometer features Hamamatsu InGaAs linear image sensors, with TEC cooling, up to -20 °C, which makes the detector less noisy, which makes it more suitable for low-light detection; the signal-to-noise ratio and dynamic range can reach 15000:1. 

Continuing the high-throughput structure design of HiNa series, F/2 can not only fully couple the input from 0.22NA fiber, but also has design redundancy, which can be compatible with unique fiber with a larger numerical aperture or customized input optical paths.



2. Powerful PC software

The PC software provided with the spectrometer-FLAVOR is powerful software. In addition to the basic spectrum acquisition control functions, it also has functions such as saturation and automatic adjustment of the integration time, recording of the real integration time, and automatic peak finding. At the same time, the software also includes characteristic functions such as wavelet smoothing with patented technology.

SDK supports Windows, Android, and Linux operating systems, and can provide secondary development packages in C#, C++, Java, Python, and other languages.


3. High stability

0~40℃, the spectral resolution remains unchanged, which is the best choice for industrial applications.


4. Simple to use

No configuration, preheating, plug and play

Separate 5V DC power supply


Product specifications and Brochures

Product Brochure Link:  


Wavelength Range

900 - 2500nm, depending on the grating

Resolution

3nm FWHM or above

Total Number of Pixels

256pixels or 512 pixels (model number with the end of  'p')

Detector

G11508-SA, 900-1700nm, the maximum cooling is lower than ambient temperature of 40°C.

G11477-WB, 900-2200nm, the maximum cooling is lower than ambient temperature of 50°C.

G11478-WB, 900-2500nm, the maximum cooling is lower than ambient temperature of 50°C.

Dynamic Range

14,000:1

Signal to Noise Ratio

10,000:1

Integration Time

5us - 120s

 F/# 2.0
 Grating
25um, 50um, 100um, 200um 
 Plug and play
SMA905 or FC/PC 
 Size/Weight170 x 179 x 64.5mm / 1.5kg
OEM/Customization

Contact us for customization


Configuration Example




Wavelength, Slit and Optical Resolution Specifications


Model

Wavelength

Range

Resolution for different Slit Width
25 um50 um100 um200 um
N/900-1700p900-1700nm3nm5nm10nm20nm
N/900-2200900-2200nm/10nm16nm32nm
N/900-2200p900-2200nm5nm8nm16nm32nm
N/900-2500p900-2500nm6nm9nm18nm36nm


Accessories

For more information on customized accessories, please contact us info@simtrum.com

Model   No.TypeWavelengthCore DiameterLength# of FiberConnector
I1000-S/S-L2Optic Fiber360~2500 nm1000 μm2 m1SMA905-SMA905
V1000-S/S-L2200 ~ 1100 nm1000μm2 m1SMA905-SMA905
DV600-S/S-L2190~1100 nm600μm2 m1SMA905-SMA905
I600-S/S-L2360~2500 nm600μm2 m1SMA905-SMA905
V600-S/S-L2200 ~ 1100 nm600μm2 m1SMA905-SMA905
DV400-S/S-L2190~1100 nm400μm2 m1SMA905-SMA905
I400-S/S-L2360~2500 nm400μm2 m1SMA905-SMA905
V400-S/S-L2200 ~ 1100 nm400μm2 m1SMA905-SMA905
DV200-S/S-L2190~1100 nm200μm2 m1SMA905-SMA905
I200-S/S-L2360~2500 nm200μm2 m1SMA905-SMA905
V200-S/S-L2200 ~ 1100 nm200μm2 m1SMA905-SMA905
DV100-S/S-L2190~1100 nm100μm2 m1SMA905-SMA905
I100-S/S-L2360~2500 nm100μm2 m1SMA905-SMA905
V100-S/S-L2200 ~ 1100 nm100μm2 m1SMA905-SMA905
I1000-Y*2-S/S-L2

Bifurcated Fiber,

 Y-bundle : 2 fibers

360~2500nm1000μm2 mA-2nos, B1-1nos, B2-1nosA-SMA905 / B1-SMA905 / B2-SMA905
V1000-Y*2-S/S-L2200 ~ 1100 nm1000μm2 mA-2nos, B1-1nos, B2-1nosA-SMA905 / B1-SMA905 / B2-SMA906
DV600-Y*7-S/S-L2190~1100 nm600μm2 mA-7nos, B1-1nos, B2-6nosA-SMA905 / B1-SMA905 / B2-SMA907
I600-Y*7-S/S-L2360~2500nm600μm2 mA-7nos, B1-1nos, B2-6nosA-SMA905 / B1-SMA905 / B2-SMA908
DV600-1*7-S/S-L2Multi-core Fiber190~1100 nm600μm2 m7SMA905-SMA905
I600-1*7-S/S-L2360~2500nm600μm27SMA905-SMA905


Integrating Sphere

Wavelength 250 - 2500 nm

Output port customizable

Black anodized aluminum alloy housing

Gold Coated Integrating Spheres

Wavelength 1000 - 5000 nm

Electrochemically plated diffuse reflective film coating

Halogen Light Source

Wavelength 360 - 2500 nm

Long lifetime, typically 10,000 hours

SMA905 output connector

Deuterium UV Light Source

Wavelength 190 - 400 nm

Long lifetime, typically 1500 hours

SMA905 output connector

Sample Holder with Mounting for Transmittance MeasurementSample Holder with Mounting for Reflectance Measurement
Cuvette HoldersOptical Mount for Transmittance and Reflectance Sample Measurement

Fiber Optic Attenuator

Wavelength 200 - 2500 nm

Adjustable slit for attenuation

Fiber Collimator

Wavelength 185 - 2500 nm

Numerical aperture 0.22 - 0.37 NA,

fiber core diameter ≥ 100 µm


Software Interface


Main software user interface

1.Detection Panel  (Function menu and operation buttons)

2.Device Panel (Device list and paremeter settings)

3.Spectral Window (Spectral curve display and spectral window management)

4.Spectral Recording Panel (Spectral curve selection and naming)


Key Spectral processing feature 

● Wavelength Smoothing 

● Defluoresence 

● Substract the background signal

● Rransmission and reflection measurement 

● Absobance measurement 

● Multi measurement with different timing

For detail software user manual please Click here


Because of the limited number of pixels in the spectrometer detector, there is a situation where only a few pixels make up a single spectral peak at the high spectral resolution, resulting in an unsmoothed peak, as shown in the figure below.

Because of the limited number of pixels in the spectrometer detector, there is a situation where only a few pixels make up a single spectral peak at the high spectral resolution, resulting in an unsmoothed peak, as shown in the figure below.


The figure shows an example of a drift in the peak position due to the temperature drift of the spectrometer at different temperatures for the same spectral peak. The spectral peaks are not symmetrical because the number of pixels that make up the spectral peaks is small, and the highest pixel of the spectral peak is shifted by one pixel from do to right under the effect of temperature drift.


At this point, we have two ways to evaluate the drift of this peak position.

1. Look at the position of the highest pixel point. Obviously, the peak position is shifted by one pixel, which translates to about 0.15 nm.

2. Fit the peaks before and after the drift and find the peak point of the fit, which is between two pixels. The drift of the fitted peak point is about 0.07nm

 

So which of these two methods is the right one? We believe that the second one is correct and reflects the true drift of the peak position. The reasons are as follows.

1. The high resolution leads to a low sampling rate of the pixels of the spectral peaks, and directly looking at the shape of the pixels together does not reflect the actual shape of the peaks.

2. The spectral peaks are physically closer to the symmetric distribution, and the drift of the peak position does not cause the peak shape to change.

3. By fitting all the pixels that make up the spectral peaks, the peak shape obtained is closer to the physical reality of the peaks.


Therefore, using the fitted peak shape to determine the peak position and evaluate the drift of the spectrometer is the correct method.


In practice, is it all necessary to do so? It depends on the situation.


If 1. The spectral resolution is low, and the sampling rate of the spectral peaks is high, i.e., it takes more pixel points to compose a peak, and these pixel points themselves are connected into a smoother and more symmetrical peak shape, then you can directly find the position of the highest pixel, or between two pixels, and confirm the peak position by visual evaluation.


2. With High spectral resolution and the need to know precisely the peak value, the above fitting method is needed. The fitting can be done by Spline algorithm, or by Gaussian or Lorentzian fitting, and the reader can choose according to the spectral nature of the sample under test. If you don't know how to choose, use Spline.



Name Model Wavelength Range Detector Resolution Noise Ratio Dynamic Range

High Resolution Spectrometer

L Sereis 200-1100nm Hamamatsu,S11639,2048 pixels <1nm customizable 500:1 2000:1

High Resolution Spectrometer

H Series 200-1100nm Hamamatsu,S11639,2048 pixels <1nm customizable 500:1 2000:1

Back Illuminated Spectrometer

M Series 200-1100nm Hamamatsu,S10420,64×2048 pixels <1nm customizable 800:1 5000:1

Hi Sensitivity Cooled Spectrometer 

MC Serie 200-1100nm Hamamatsu,S7031,64×1044 pixels <1nm customizable 1000:1 10000:1

Handheld Raman System 

RM 785/1064nm

Band Range 

200-3200cm-1/ 200-2500cm-1

6 - 8 cm-1    

Portable Tabletop Raman System

RMT EZ 785nm Band Range  200-3200cm-1
7 cm-1  typical    

Portable Tabletop Raman System

RMT 532/785/1064nm

Band Range 

200-3200cm-1/200-1800cm-1

8 - 9 cm-1 typical
   

NIR Spectrometer 

NIR Series 900-2500nm Hamamatsu, G9203 3-10nm 15000:1 15000:1

MWIR Spectrometer 

MWIR Series 1-5um PbS or PbSe  256 pixels 10-30nm 20 RMS  

 

Laser Scanning Confocal Microscope
Wide Field Raman Microscope 
Fluorescence / Photoluminescence Microscope

We are here for you!




Drop us an email at info@simtrum.com to get the Best Price today.

Want more technical information? Click Here for the professional Customized System/ Solutions.




Don't have time to search the products one by one? No worries. you can download the full range of SIMTRUM Product Line Cards.

Click it now.


Want to stay closer to the Market Dynamics and Technological Developments? Just take 5 seconds to Sign In as a member of SIMTRUM, we will bring you the most up-to-date news. 

(Sign in button on the top right of the screen).




Search Reset
Compare Model Drawings & Specs Availability Reference Price
(USD)
N/900-1700p
Near Infrared Spectrometer, Wavelength range: 900-1700nm, Resolution up to 3nm @25um slit width, 512 pixels, dynamic range 14000:1, signal to noise ratio 10000:1 integration time 5us-120s
4-6 Weeks $17000 - 21000
N/900-2200p
Near Infrared Spectrometer, Wavelength range: 900-2200nm, Resolution up to 5nm @25um slit width, 512 pixels, dynamic range 14000:1, signal to noise ratio 10000:1 integration time 5us-120s
4-6 Weeks $25000 - 30000
N/900-2500p
Near Infrared Spectrometer, Wavelength range: 900-2500nm, Resolution up to 6nm @25um slit width, 512 pixels, dynamic range 14000:1, signal to noise ratio 10000:1 integration time 5us-120s
8-10 Weeks $25000 - 30000

N/900-2500p - Parameter

N/900-2200p - Parameter

N/900-1700p - Parameter

DV600-1*7-S/S-L2 - Parameter

I600-1*7-S/S-L2 - Parameter

I600-Y*7-S/S-L2 - Parameter

DV600-Y*7-S/S-L2 - Parameter

V1000-Y*2-S/S-L2 - Parameter

I1000-Y*2-S/S-L2 - Parameter

V100-S/S-L2 - Parameter

I100-S/S-L2 - Parameter

DV100-S/S-L2 - Parameter

V200-S/S-L2 - Parameter

I200-S/S-L2 - Parameter

DV200-S/S-L2 - Parameter

V400-S/S-L2 - Parameter

I400-S/S-L2 - Parameter

DV400-S/S-L2 - Parameter

V600-S/S-L2 - Parameter

I600-S/S-L2 - Parameter

DV600-S/S-L2 - Parameter

V1000-S/S-L2 - Parameter

I1000-S/S-L2 - Parameter

N/900-2500p - Download

N/900-2200p - Download

N/900-1700p - Download

DV600-1*7-S/S-L2 - Download

I600-1*7-S/S-L2 - Download

I600-Y*7-S/S-L2 - Download

DV600-Y*7-S/S-L2 - Download

V1000-Y*2-S/S-L2 - Download

I1000-Y*2-S/S-L2 - Download

V100-S/S-L2 - Download

I100-S/S-L2 - Download

DV100-S/S-L2 - Download

V200-S/S-L2 - Download

I200-S/S-L2 - Download

DV200-S/S-L2 - Download

V400-S/S-L2 - Download

I400-S/S-L2 - Download

DV400-S/S-L2 - Download

V600-S/S-L2 - Download

I600-S/S-L2 - Download

DV600-S/S-L2 - Download

V1000-S/S-L2 - Download

I1000-S/S-L2 - Download

Accessories

Compare Model Drawings & Specs Availability Reference Price
(USD)
I1000-S/S-L2
Optic Fiber, Wavelength 360-2500 nm, Number of Fiber 1nos, Core Diameter 1000 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $384.00
V1000-S/S-L2
Optic Fiber, Wavelength 200-1100 nm, Number of Fiber 1nos, Core Diameter 1000 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $374.00
DV600-S/S-L2
Optic Fiber, Wavelength 190-1100 nm, Number of Fiber1nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package 5.5 Blue armored tubing
2-3 Weeks $324.00
I600-S/S-L2
Optic Fiber, Wavelength 360-2500 nm, Number of Fiber 1nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $202.00
V600-S/S-L2
Optic Fiber, Wavelength 200-1100 nm, Number of Fiber 1nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $188.00
DV400-S/S-L2
Optic Fiber, Wavelength 190-1100 nm, Number of Fiber 1nos, Core Diameter 400 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $192.00
I400-S/S-L2
Optic Fiber, Wavelength 360-2500 nm, Number of Fiber 1nos, Core Diameter 400 um, Length 2M, Connector SMA905-SMA905, Package 5.5 blue armored tubing
2-3 Weeks $172.00
V400-S/S-L2
Optic Fiber, Wavelength 200-1100 nm, Number of Fiber 1nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package 5.5 blue armored tubing
2-3 Weeks $172.00
DV200-S/S-L2
Optic Fiber, Wavelength 190-1100 nm, Number of Fiber 1nos, Core Diameter 200 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $162.00
I200-S/S-L2
Optic Fiber, Wavelength 360-2500 nm, Number of Fiber 1nos, Core Diameter 200 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $142.00
V200-S/S-L2
Optic Fiber, Wavelength 200-1100 nm, Core Number 1nos, Core Diameter 200 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $142.00
DV100-S/S-L2
Optic Fiber, Wavelength 190-1100 nm, Core Number 1nos, Core Diameter 100 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $162.00
I100-S/S-L2
Optic Fiber, Wavelength 360-2500 nm, Core Number 1nos, Core Diameter 100 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $142.00
V100-S/S-L2
Optic Fiber, Wavelength 200-1100 nm, Core Number 1nos, Core Diameter 100 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $142.00
I1000-Y*2-S/S-L2
Bifurcated Fiber, Y-bundle: 2 fibers , Wavelength 360-2500 nm, Core Diameter 1000 um, Length 2M, Connector SMA905-SMA905, Package 6.0 armored tubing
2-3 Weeks $647.00
V1000-Y*2-S/S-L2
Bifurcated Fiber, Y-bundle: 2 fibers, Wavelength 200-1100 nm, Core Diameter 1000 um, Length 2M, Connector SMA905-SMA905, Package 6.0 armored tubing
2-3 Weeks $465.00
DV600-Y*7-S/S-L2
Bifurcated Fiber, Y-bundle: 7 fibers, Wavelength 190-1100 nm, Core Number A-7nos, B1-1nos, B2 - 6nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905,Package PVC
2-3 Weeks $1264.00
I600-Y*7-S/S-L2
Bifurcated Fiber, Y-bundle: 2 fibers , Wavelength 360-2500 nm, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $1007.00
I600-1*7-S/S-L2
Multi-core Fiber, Wavelength 360-2500 nm, Number of Fiber 7nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $967.00
DV600-1*7-S/S-L2
Multi-core Fiber, Wavelength 190-1100 nm, Core Number 7nos, Core Diameter 600 um, Length 2M, Connector SMA905-SMA905, Package PVC
2-3 Weeks $1214.00