Sign In

  • Forgot your password?
  • Need a new account?

Register


STRSPD-305-STD

Near-infrared Single Photon Detector 900-1700nm, Trigger Frequency Outside 1-100MHz, Gate width 1ns, Dark Count Rate STD: ≤ 6.0e-6/gate @ 20%SPDE ULN: ≤ 0.5e-6/gate @ 20%SPDE, Single Photon Detectione Ficiency 10% 15% 20%(default) 25% (±1%) (30% per request)

MODEL:STRSPD-305-STD

4-6 Weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
STRSPD-305-ULN
Near-infrared Single Photon Detector 900-1700nm, Trigger Frequency Outside 1-100MHz, Gate width 1ns, Dark Count Rate STD: ≤ 6.0e-6/gate @ 20%SPDE ULN: ≤ 0.5e-6/gate @ 20%SPDE, Single Photon Detectione Ficiency 10% 15% 20%(default) 25% (±1%) (30% per request)
4-6 Weeks Request for quote
STRSPD-305
Near-infrared Single Photon Detector 900-1700nm, Trigger Frequency Outside 0.1-100MHz, Gate width 1ns, Dark Count Rate ≤2e-6/gate @10%SPDE, Single Photon Detectione Ficiency 5%,10%,15%, 20% optional
4-6 Weeks Request for quote

Compatible

Compare Model Drawings & Specs Availability Reference Price

 

Product Specifications and Brochures

Product Brochure Link: 

Technical Parameters
 Detection Wavelength Range 900~1700nm
 Trigger Frequency Outside 1-100MHz
 Gate width 1ns type.
 Effective Detection Width[1]  170ps type.
 Single Photon Detectione Ficiency [2]

10% 15% 20%(default) 25% (±1%)

(30% per request)

 Dark Count Rate

STD: 6.0e-6/gate @ 20%SPDE  

ULN: 0.5e-6/gate @ 20%SPDE

 Postpulse Probability@50MHz

1% @10%SPDE

2% @20%SPDE

5% @25%SPDE

 Cooling Time ≤5min
Other Parameters
 Recommended Operating Temperature [3]  -10~35℃
 Extreme Operating Temperature [4] -15~40℃
 Voltage 11.5V~12.5VDC
 Power Dissipation Cooling maximum power consumption <36W
Stable maximum power consumption <15W
 Dimensions(WxDxH) 72.4 x 152x 57.5mm
 Net Weight 0.95Kg

Note:
[1]The detection count drops to half of the photon count peak corresponding to the gated to photon relative time width.
[2]Single photon detection efficiency calibrated at 1550nm wavelength at room temperature 25
°C.
[3]SPAD cooling works normally, and the photon count fluctuation range does not exceed 20% of the calibrated value.
[4]SPAD cooling works normally, and the photon count fluctuation range does not exceed 50% of the calibrated value.

STRSPD-305-ULN - Parameter

STRSPD-305-STD - Parameter

STRSPD-305 - Parameter

STRSPD-305-ULN - Download

STRSPD-305-STD - Download

STRSPD-305 - Download