Sign In

  • Forgot your password?
  • Need a new account?

Register


LA-CC01-PD20-200T

Power Range 1 nW - 20 mW,Wavelength Range 200-1100nm,Active Area Diameter 10*10mm,Max. Power Density 1W/cm2,Measurement Uncertainty ±2%

MODEL:LA-CC01-PD20-200T

$1639.37 4-6week Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
LA-CC01-PD1000-200T
Power Range 1nW-1000mW,Wavelength Range 200-1100nm,Active Area Diameter 10*10mm,Max. Power Density 20W/cm2(With Attenuator);1W/cm2(Without Attenuator),Measurement Uncertainty ±2%
4-6week $2001.96
LA-CC01-PD1000-350T
Power Range 1nW-1000mW,Wavelength Range 350-1100nm,Active Area Diameter 10*10mm,Max. Power Density 20W/cm2(With Attenuator);1W/cm2(Without Attenuator),Measurement Uncertainty ±2%
4-6week $1977.14
LA-CC01-PD100-350T
Power Range1 nW - 100 mW,Wavelength Range 350-1100nm,Active Area Diameter 10*10mm,Max. Power Density 1W/cm2,Measurement Uncertainty ±2%
4-6week $1647.78

Compatible

Compare Model Drawings & Specs Availability Reference Price

Large Detection Diameter Type
Model LA-CC01-PMPEL350-100 LA-CC01-PMPEL350-1000 LA-CC01-PMPEL200-20 LA-CC01-PMPEL200-1000
  Power Range 1 nW - 100 mW 1 nW - 1000 mW 1 nW - 20 mW 1nW-1000mW
  Active Area Diameter 10*10mm
  Wavelength Range 350-1100nm 200-1100nm
  Max. Measurable Power / 1000mW(With Attenuator)
10mW(Without Attenuator)
/ 1000mW(With Attenuator)
10mW(Without Attenuator)
  Max. Power Density 1W/cm2 20W/cm2(With Attenuator)
1W/cm2(Without Attenuator)
1W/cm2 20W/cm2(With Attenuator)
1W/cm2(Without Attenuator)
  Sensitivity 1nW
  Measurement Uncertainty ±2%
  Resolution 1nW
  Accuracy <±2%

 

Other Parameters

Probe Material Si
Power Supply 18650 (2 batteries)
Computer Interface USB 1.1 and USB 2.0
Instrument Power 100-240 VAC, 50/60 Hz, DC 12V-3.34A
Temperature (Operating) 5°C - 45°C (41°F - 113°F)
Temperature (Storage) -20°C - 70°C (-4°F - 158°F)
Warranty Period 1 year
*Attention:Before testing,please pay attention to the spot size and calculate the maximum average power density.These two parameters must be with in the range of the above table.If the probe is damaged due to parameters beyond the range of abovetable,it is not be covered by the warranty.

LA-CC01-PD1000-200T - Parameter

LA-CC01-PD20-200T - Parameter

LA-CC01-PD1000-350T - Parameter

LA-CC01-PD100-350T - Parameter

LA-CC01-PD1000-200T - Download

LA-CC01-PD20-200T - Download

LA-CC01-PD1000-350T - Download

LA-CC01-PD100-350T - Download