LA-CH01-W30K

Spectral range: 0.8-2/10.6um Power range: 100W - 30kW; Detection aperture: 80mm; Maximum average power density: 10kW/cm²; Specification: Φ229 × 120mm;

MODEL:LA-CH01-W30K

4-6 Weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
LA-CH01-W15K
Spectral range: 0.8-2/10.6um; Power range: 100W - 15kW; Detection aperture: 55mm; Maximum average power density: 6kW/cm²; Specification: Φ170 × 82mm;
4-6 Weeks Request for quote
LA-CH01-W10K
Spectral range: 0.8-2/10.6um;Power range: 100W - 10kW; Detection aperture: 45mm; Maximum average power density: 3kW/cm²; Specification: Φ146 × 70mm
4-6 Weeks Request for quote
LA-CH01-W7K
Spectral range: 0.8-2/10.6um;Power range: 100W - 7kW; Detection aperture: 40mm; Maximum average power density: 3kW/cm²; Specification: Φ137 × 65mm; Cooling water flow: 5 - 10L/min
4-6 Weeks Request for quote

Compatible

Compare Model Drawings & Specs Availability Reference Price
LA-CH01-LP - P
It has functions such as digital display, data statistics and data storage Accuracy: ±0.25% Digital interface: USB2.0 ADC sampling frequency: 20Hz
4-6 Weeks Request for quote

Specifications

Model LA-CH01-W7K LA-CH01-W10K LA-CH01-W15K LA-CH01-W30K
Spectral Range (μm) 0.8 - 2, 10.6
Power Range 100W - 7kW 100W - 10kW 100W - 15kW 100W - 30kW
Measurement Capability
Resolution (W) 1
Measurement Uncertainty (±%) < 1
Non - linearity (±%) < 2
Accuracy (±%) < 5
Response Time (s) < 3
Absorber Type PT
Detection Aperture (mm) 40 45 55 80
Damage Threshold
Maximum Average Power Density 3kW/cm² 3kW/cm² 6kW/cm² 10kW/cm²
Requirements for
Incident Light Irradiation
To avoid damage to the probe, the following requirements are put forward for the irradiation position and inclination angle of the incident light beam:
  1. 1. The center of the incident light beam should irradiate the center of the probe cone. The maximum position deviation should not exceed 1/4 of the diameter of the light spot.
  2. 2. The maximum inclination angle of the incident light beam is ± 5 degrees. (for all models)
Physical Characteristics
Specification (mm) Φ137 × 65 Φ146 × 70 Φ170 × 82 Φ229 × 120
Cooling Method Water - cooling (for all models)
Cooling Water Flow (L/min) 5-10 8-10 8-15 10-30
Interface Type DB - 9M DB - 9M DB - 9M DB - 9M
Cable Length (m) 5 5 5 10
 
 

LA-CH01-LP - P - Parameter

LA-CH01-W30K - Parameter

LA-CH01-W15K - Parameter

LA-CH01-W10K - Parameter

LA-CH01-W7K - Parameter