Power Range 10 mW - 50 W,Wavelength Range 0.19-25 μm,Active Area Diameter 22 mm,Max. Average Power Density 40 kW/cm2,Linearity ±1%

MODEL:LA-CC01-USBPM-50

$1540.46 4-6week Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
LA-CC01-PD1000-200T-USB
Power Range 1nW-1000mW,Wavelength Range 200-1100nm,Active Area Diameter 10*10mm,Max. Power Density 20W/cm2(With Attenuator);1W/cm2(Without Attenuator),Measurement Uncertainty ±2%
In Stock $1701.84
LA-CC01-PD20-200T-USB
Power Range 1 nW - 20 mW,Wavelength Range 200-1100nm,Active Area Diameter 10*10mm,Max. Power Density 1W/cm2,Measurement Uncertainty ±2%
4-6week $1392.30
LA-CC01-PD1000-350T-USB
Wavelength Range 350-1100nm,Active Area Diameter 10*10mm,Max. Power Density 20W/cm2(With Attenuator);1W/cm2(Without Attenuator),Measurement Uncertainty ±2%
4-6week $1680.62
LA-CC01-PD100-350T-USB
Power Range 1 nW - 100 mW,Wavelength Range 350-1100nm,Active Area Diameter 10*10mm,Max. Power Density 1W/cm2,Measurement Uncertainty ±2%
4-6week $1400.51
LA-CC01-USBPM-HA-5
Power Range 100 µW - 5 W,Wavelength Range 0.19-20 μm,Active Area Diameter 9 mm,Max. Average Power Density 1.5 kW/cm2,Linearity ±0.2%
4-6week $1891.44
LA-CC01-USBPM-HA-1
Power Range 100 µW - 1 W,Wavelength Range 0.19-20 μm,Active Area Diameter 9 mm,Max. Average Power Density 1.5 kW/cm2,Linearity ±0.2%
4-6week $1891.44
LA-CC01-USBPM-200
Power Range 50mW- 200 W,Wavelength Range 0.19-25 μm,Active Area Diameter 25 mm,Max. Average Power Density 45 kW/cm2,Linearity ±1%
4-6week $2801.03
LA-CC01-USBPM-100
Power Range 50mW - 100 W,Wavelength Range 0.19-25 μm,Active Area Diameter 25 mm,Max. Average Power Density 45 kW/cm2,Linearity ±1%
4-6week $2801.03
LA-CC01-USBPM-35
Power Range 10 mW - 35 W,Wavelength Range 0.19-25 μm,Active Area Diameter 22 mm,Max. Average Power Density 40 kW/cm2,Linearity ±1%
4-6week $1540.46
LA-CC01-USBPM-15
Power Range 2 mW - 15 W,Wavelength Range 0.19-25 μm,Active Area Diameter 22 mm,Max. Average Power Density 15 kW/cm2,Linearity ±1%
4-6week $1471.59
LA-CC01-USBPM-5
Power Range 2 mW - 5 W,Wavelength Range 0.19-25 μm,Active Area Diameter 22 mm,Max. Average Power Density 15 kW/cm2,Linearity ±1%
4-6week $1471.59
LA-CC01-USBPM-2
Power Range 2 mW - 2 W,Wavelength Range 0.19-25 μm,Active Area Diameter 22 mm,Max. Average Power Density 15 kW/cm2,Linearity ±1%
4-6week $1417.59

Compatible

Compare Model Drawings & Specs Availability Reference Price

Thermoelectric type
Model LA-CC01-USBPM-2 LA-CC01-USBPM-5 LA-CC01-USBPM-15  LA-CC01-USBPM-35 LA-CC01-USBPM-50   LA-CC01-USBPM-100    LA-CC01-USBPM-200    LA-CC01-USBPM-HA-1   LA-CC01-USBPM-HA-5
  Power Range 2 mW - 2 W 2 mW - 5 W 2 mW - 15 W 10 mW - 35 W 10 mW - 50 W 50mW - 100 W 50mW- 200 W 100 µW - 1 W 100 µW - 5 W
  Active Area Diameter 22 mm 25 mm 9 mm
  Wavelength Range 0.19-25 μm 0.19-20 μm
  Max. Average Power Density 15 kW/cm2 40 kW/cm2 45 kW/cm2 1.5 kW/cm2
  Max. Energy Density 0.15J/cm2,1064nm,1ns 0.3J/cm2,1064nm,7ns 0.3J/cm2(1 ns Pulse)
  Sensitivity 2 mW 10 mW 50mW 100 µW
  Measurement Uncertainty ±2%
  Response Time (0-90%) <1 sec.
  Linearity ±1% ±0.2%
  Resolution 100uW 1mW 10mW 10uW
  Accuracy <±2%
 
Other Parameters
Probe Coating Film Broadband coating
  Probe Material Thermopile
  Cooling Method Air cooling(TS2/5/15/35/50 and HS1/5)
Fan cooling(TS100/200/300)
  Computer Interface USB 1.1 and USB 2.0
  Instrument Power 100-240 VAC, 50/60 Hz, DC 12V-3.34A
  Temperature (Operating) 5°C - 45°C (41°F - 113°F)
  Temperature (Storage) -20°C - 70°C (-4°F - 158°F)
  Warranty Period 1 year

 

Photoelectric type

Model LA-CC01-PD-100-350T-USB LA-CC01-PD-1000-350T-USB LA-CC01-PD-20-200T-USB LA-CC01-PD-1000-200T-USB
  Power Range 1 nW - 100 mW 1 nW - 1000 mW 1 nW - 20 mW 1nW-1000mW
  Active Area Diameter 10*10mm 10*10mm 10*10mm 10*10 mm
  Wavelength Range 350-1100nm / 200-1100nm 200-1100nm
  Max. Measurable Power / 1000mW(With Attenuator)
10mW(Without Attenuator)
/ 1000mW(With Attenuator)
10mW(Without Attenuator)
  Max. Power Density 1W/cm2 20W/cm2(With Attenuator)
1W/cm2(Without Attenuator)
1W/cm2 20W/cm2(With Attenuator)
1W/cm2(Without Attenuator)
  Sensitivity 1nW
  Measurement Uncertainty ±2%
  Resolution 1nW
  Accuracy <±2%
 
 
Other Parameters
Probe Material Si
Computer Interface USB 1.1 and USB 2.0
Temperature (Operating) 5°C - 45°C (41°F - 113°F)
Temperature (Storage) -20°C - 70°C (-4°F - 158°F)
Warranty Period 1 year
 

LA-CC01-PD1000-200T-USB - Parameter

LA-CC01-PD20-200T-USB - Parameter

LA-CC01-PD1000-350T-USB - Parameter

LA-CC01-PD100-350T-USB - Parameter

LA-CC01-USBPM-HA-5 - Parameter

LA-CC01-USBPM-HA-1 - Parameter

LA-CC01-USBPM-200 - Parameter

LA-CC01-USBPM-100 - Parameter

LA-CC01-USBPM-50 - Parameter

LA-CC01-USBPM-35 - Parameter

LA-CC01-USBPM-15 - Parameter

LA-CC01-USBPM-5 - Parameter

LA-CC01-USBPM-2 - Parameter

LA-CC01-PD1000-200T-USB - Download

LA-CC01-PD20-200T-USB - Download

LA-CC01-PD1000-350T-USB - Download

LA-CC01-PD100-350T-USB - Download

LA-CC01-USBPM-HA-5 - Download

LA-CC01-USBPM-HA-1 - Download

LA-CC01-USBPM-200 - Download

LA-CC01-USBPM-100 - Download

LA-CC01-USBPM-50 - Download

LA-CC01-USBPM-35 - Download

LA-CC01-USBPM-15 - Download

LA-CC01-USBPM-5 - Download

LA-CC01-USBPM-2 - Download