SIMSCOP Raman S2

SIMSCOP Confocal/PL Raman Microscope , Multi-channel laser up to 5 channels, wavelengths 405nm/532nm/638nm/785nm/1064nm, Laser power 100mW, linewidth 0.001nm, Near-infrared spectrum support, Raman range typical 150~3200cm-1, Confocal image resolution ~200nm @100x objective, Electric continuously variable speed pinhole mode, spot size ~1um@50x, Compatible with upright/inverted microscopes, Compatible with standard stretching stages, high/low-temperature stages, in-situ stages, and vacuum stages

MODEL:SIMSCOP Raman S2

6-8 weeks Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
Industry Line Scan Confocal Microscope
Industry Line Scan Confocal Microscope,Standart wavelength:405nm±5nm,Output way:Single-mode polarization-maintaining fiber coupling (TEM00),Single wavelength output power:>20mW,Power stability:<1%,Spectrum Linewidth<3nm
In Stock Request for quote
Automated Fluorescence Microscope
Automatic fluorescence microscope,can be selected as an upright or inverted microscope, customer-customized
In Stock Request for quote
SIMSCOP Raman S1
SIMSCOP Confocal/PL Raman Microscope , Single-channel laser, wavelengths 532nm/638nm/785nm optional, Laser power 100mW, linewidth 0.003nm, Raman range typical 150~3200cm-1, Confocal image resolution ~200nm @100x objective, manual pinhole mode, spot size ~1um@50x, Compatible with upright/inverted microscopes,Compatible with standard stretching stages, high/low-temperature stages, in-situ stages, and vacuum stages
6-8 weeks Request for quote
DermDive
Wideband Handheld Confocal Raman Skin Analyzer, Detection Range: FP: 450 – 1750cm-1; HW: 2800-3750cm-1, Axial Resolution: 10um~20um, Sensitivity: 60dB, Scanning Time: 2-10s/depth
6-8 Weeks Request for quote
SpinDisk SIM
Structured Illumination Microscope, SIM Basic, Image frame rate 13fps@1024x1024, Resolution ~100nm, image depth <50um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution
6-10 Weeks Request for quote
SIM Basic
Structured Illumination Microscope, SIM Basic, Image frame rate 13fps@1024x1024, Resolution ~100nm, image depth <50um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution
6-10 Weeks Request for quote
SpinDisk Advance
Spinning Disk Confocal Microscope, SpinDisk Advance Series, Image frame rate 100fps@2048x2048, Resolution ~230nm, image depth <200um, No. of Laser - 4, Wavelength choice 405/445/470/520/528/555/640nm, Dual sCMOS Camera detectors (single sCOMS optional), Inverted or upright microscope, XYZ motorized stages, Motorized filter electronics system, high image contrast, upgrade to SpinDisk SIM 100nm resolution, customized option
6-10 Weeks Request for quote
SpinDisk Basic Spinning Disk Confocal Microscope
Spinning Disk Confocal Microscope, SpinDisk Basic Series, Image frame rate 100fps@2048x2048, Resolution ~230nm, image depth <200um, No. of Laser - 4, Wavelength choice 405/445/488/525/561/640nm, sCMOS Camera detectors, Inverted or upright microscope, XYZ motorized stages, high image contrast, customized option
6-10 Weeks Request for quote
Research Line Scan Confocal Microscope L Series
Research Line Scan Confocal Microscope L Series,Standard wavelength 405±5nm/488nm±5nm/561nm±1nm/640nm±5nm,Laser power adjust accuracy:0.1%, Multi-wavelength AOTF adjustment power,Single wavelength output power:>20mW,Power stability:<1%,Spectrum Linewidth<3nm
6-10 Weeks Request for quote
MIC-PL(XXX)
Fluorescence/Photoluminescence Microscope (System), Detector Hamamatsu area array back-illuminated CCD, cooling temperature -15 °C 6M Camera ,3072x2048, pixel size 2.4um. Spot size up to the diffraction limit (1um @50x objective lens @532nm). 3D dynamic scanning or 2D dynamic scanning optional.
4-6weeks Request for quote
SIMSCOP P Series
Laser Scanning Confocal Microscope, Standard Wavelength 405/488/561/640nm(638nm), dual-axis XY high-speed optical scanning galvanometer, field of view 15x15mm, scanning pixels 512x512 ~4096x4096, scan speed up to 4fps, stroke: X-110mm, Y-75mm, Z-9mm
In Stock Request for quote

Compatible

Compare Model Drawings & Specs Availability Reference Price

Standard System specifications and Brochures

Product Brochure Link: 

 

Model SIMSCOP-RAMAN-S1 SIMSCOP-RAMAN-S2
Laser Single-channel laser: 1 channel
Wavelengths: 532 nm, 638 nm, 785 nm optional
Power: 100mW, Linewidth: 0.003nm, Power stability: 1%
Multi-channel laser: Up to 5 channels
Wavelengths: 405nm, 532 nm, 638 nm, 785 nm, 1064 nm
Power: 100mW, Linewidth: 0.001nm, Power stability: 1%
Near-infrared spectrum support
Compatible Spectrometers Fiber spectrometer / Third-party large spectrometers (Horiba, Andor, etc.)
Spectral Resolution Fiber spectrometer: ≤4cm⁻¹ / Third-party large spectrometer: ≤1.23cm⁻¹
Spectral Range 50 cm⁻¹ – 15,000 cm⁻¹ (customizable)
Fiber Spectrometer Detector Options Option 1: M Series - Hamamatsu S10420 2048 x 64 pixels, Cooled BSI
Option 2: MC Series - Hamamatsu S7031-1006S  1044 x 64 pixels, Cooled BSI CCD
Option 3: HiNA Series - E2V  2000 x 264 Pixel -70°C Cooled BSI CCD
Dark Current <0.001e⁻/pixel/s
Wide-field Camera CMOS back-illuminated camera
15FPS@5440x3648; 50FPS@2736x1824; 60FPS@1824x1216
Confocal Mode Manual pinhole Electric continuously variable speed pinhole
Confocal Imaging Resolution ~200nm @100x objective
Spot Size ~1um @50x
Sample Stage XY electric (manual optional),
Z manual (upgradeable to electric),
Repeat positioning accuracy: ±0.25μm
XYZ electric, Repeat positioning accuracy: ±0.25μm
Travel Distance XY: 50mm*50mm, Z: 150mm (customizable)
Load Capacity 10KG
Sample Stage Compatibility Compatible with standard stretching stages, high/low-temperature stages,
in-situ stages, and vacuum stages
Microscope Compatibility Compatible with upright/inverted microscopes
Objectives (Optional) Long working distance 10X objective NA: ≥0.25; WD: ≥30mm; Resolution: ≤1um
Long working distance 20X objective NA: ≥0.40; WD: ≥20mm; Resolution: ≤0.80um
Long working distance 50X objective NA: ≥0.50; WD: ≥10mm; Resolution: ≤0.60um
Software Standard Software Features Advanced Features
1.Z-axis Autofocus
2.Confocal Adaptive Pinhole
3.Multi-dimensional Scanning Imaging
4.Advance Raman Spectroscopy Processing



Industry Line Scan Confocal Microscope - Parameter

Automated Fluorescence Microscope  - Parameter

SIMSCOP Raman S2 - Parameter

SIMSCOP Raman S1 - Parameter

DermDive - Parameter

SpinDisk SIM - Parameter

SIM Basic - Parameter

SpinDisk Advance - Parameter

SpinDisk Basic Spinning Disk Confocal Microscope - Parameter

Research Line Scan Confocal Microscope L Series - Parameter

MIC-PL(XXX) - Parameter

SIMSCOP P Series - Parameter

Industry Line Scan Confocal Microscope - Download

Automated Fluorescence Microscope  - Download

SIMSCOP Raman S2 - Download

SIMSCOP Raman S1 - Download

DermDive - Download

SpinDisk SIM - Download

SIM Basic - Download

SpinDisk Advance - Download

SpinDisk Basic Spinning Disk Confocal Microscope - Download

Research Line Scan Confocal Microscope L Series - Download

MIC-PL(XXX) - Download

SIMSCOP P Series - Download