Sign In

  • Forgot your password?
  • Need a new account?

Register


IM-TCM2C

USB output, for connection to a computer, comes with temperature measurement software, and has two 1.5m temperature measurement wires

MODEL:IM-TCM2C

$33.35 Contact us Drawings

Save To My List

* The prices are indicative only. Please contact us for an official quote. This is single product page, for detail specification please refer to product main page


Compare Model Drawings & Specs Availability Reference Price
IM-TCM8C
USB output, for connection to a computer, comes with temperature measurement software and eight 1.5m temperature measurement wires
Contact us $152.62
IM-TCM4C
USB output, for connection to a computer, comes with temperature measurement software, and has four 1.5m temperature measurement wires
Contact us $80.80
IM-TCM1C
USB output, for connection to a computer, comes with temperature measurement software, and features a single 1.5m temperature measurement cable
Contact us $22.23

Compatible

Compare Model Drawings & Specs Availability Reference Price

Technical indicators

IM-TCM1C

IM-TCM2C

IM-TCM4C

IM-TCM8C

Supply voltage

USB built-in 5V (no external power supply required)

Power supply current

10mA

50mA

Temperature measurement range

-200~1360℃

Temperature measurement accuracy [1]

±0.4℃/±0.2% FS

±0.3℃/±0.15% FS

Temperature resolution

0.01℃(20位分辨率@25Hz)

Repeatability accuracy [2]

±0.25℃

Between channels:±0.25℃,Inside the channel:±0.2℃

Sampling rate

0.0Hz、0.2Hz、0.5Hz、1Hz、2Hz、5Hz、10Hz、15Hz、60Hz(多种采样频率可设置)

Overvoltage protection [3]

Isolation voltagebetween USB and thermocouple:

1500V

Isolation voltage between USB and thermocouple: 1500V

Channel overvoltage protection: ±45V (If the pressure difference between channels is greater than this value, there may be a risk of damaging the instrument.)

The number of thermocouples And type

Single-channel K-type

Dual-channel K-type

4-channel K-type

8-channel K-type

Thermocouple matching

Standard K-type thermocouple wire is provided. Wire lengths are available in 1.5m, 3m and 5m
(other wire lengths can be customized).

Standard size of thermocouple

Specification: K type (nickel-chromium - nickel-aluminum) 2x0.3mm, Wire diameter: 1.2×1.7mm(≈0.1mm

The temperature resistance of the probe tip is less than 1360℃, and the temperature resistance of the thermocouple coating is less than 280℃

Thermocouple interface

Direct welding type, no connector

Micro thermocouple plug/socket

Secondary development support

Provide SDK dynamic link library (USB)

The device also offers a serial port support version.
Please specify when placing an order (supports Modbus-RTU protocol).

Supporting software

Thermmonitor

Collection equipment

Windows7 and above devices

Communication method

The USB driver-free human-machine interaction interface device also offers a serial port version.
Please specify when placing an order (supports Modbus-RTU protocol).

Applicable scenarios

Measure the temperature of solids, liquids and gases

Operating temperature range

-20~80℃

Operating relative humidity

0-95% (No condensation)

Note

[1] The maximum deviation between the temperature measurement value of the thermocouple and the international standard thermocouple within the full range of 1500℃ was measured in a constant temperature environment of 25℃±5℃, with absolute accuracy measured within the range of 0-100℃.

[2] When a single channel or multiple channels are simultaneously used to measure the same constant-temperature object, the statistical error of the measurement results at a frequency of 1Hz is obtained in a constant-temperature environment of 25℃±5℃.

[3] Do not use thermocouples to directly measure the temperature of live objects. If it is necessary to measure the temperature of live objects, the probe must be insulated and protected. The voltage difference between multi-channel thermocouples should not exceed 45V; otherwise, the instrument may be damaged due to breakdown.

IM-TCM8C - Parameter

IM-TCM4C - Parameter

IM-TCM2C - Parameter

IM-TCM1C - Parameter

IM-TCM8C - Download

IM-TCM4C - Download

IM-TCM2C - Download

IM-TCM1C - Download